Georim in Dubai: Bilge Alarms, OWS and Local Service for MARPOL Compliance

Georim in Dubai

Georim supplies 15 ppm bilge alarms, oily water separators and discharge loggers used widely on commercial vessels. This article explains who represents Georim in the UAE, which products matter for MARPOL Annex I, and how local service, calibration and documentation work in Dubai and nearby ports.

TL;DR: 

  • Best Georim systems (GBA-155, Green Box, OWS) are available in Dubai through an authorized agent with onboard calibration, repair and retrofit support.
  • Al Ghwasa is the regional sales and service contact for Georim equipment in the Middle East; they handle spare parts and certificates.
  • MEPC rules require accurate 15 ppm alarms and auditable discharge logs; regular calibration and class-accepted certificates prevent PSC detentions.

Brand & Local Representation

Summary: An authorized local agent manages sales, spares and on-site service for Georim in the UAE.

Definition: an authorized agent handles warranty, genuine spare parts, and certified calibration for the manufacturer. Example: Al Ghwasa lists Georim representation for the Middle East and provides a Dubai office address and contact details.

Insight: using an authorized agent reduces risks from counterfeit parts and missing documentation.

Who is the authorized Georim agent in Dubai/UAE?

Summary: Al Ghwasa Technical Eqpt Tdg LLC acts as Georim’s authorized sales and service agent in the Middle East.

Definition: authorized agent means direct manufacturer support and legitimate spare sourcing. Example: the agency page confirms representation, product listings and Dubai contact details. Tip: ask for written confirmation of authorization and warranty transfer when buying.

How to contact the local Georim representative?

Summary: Contact details appear on the local agent landing page for quotations, spare parts and service bookings.

Definition: the landing page includes office address, phone and PO Box for Dubai. Example: use the agent link to request a quotation for GBA-155 calibration or spare kits. Keep a copy of service agreements and calibration certificates.

Products: Bilge Alarm, OWS, Green Box

Summary: The core Georim product set covers the GBA-155 bilge alarm, Green Box recorder and multiple oily water separator models.

Definition: GBA-155 is a certified 15 ppm bilge alarm; Green Box is a discharge logger; OWS units handle mechanical separation and polishing. Example use: a tanker installs GBA-155 and Green Box to supply PSC-ready logs.

Georim GBA-155 15 ppm bilge alarm — specs and use

Summary: The GBA-155 detects oil concentration to 15 ppm and triggers alarms per MEPC guidance.

Definition: a 15 ppm bilge alarm measures oil in effluent and warns before discharge. Example specs: 0–30 ppm measurement range and alarm thresholds at 5 or 15 ppm. Important: keep calibration records and test logs for inspections.

Green Box discharge logger — what it records

Summary: The Green Box logs time, GPS position, discharge status and volume to create an auditable trail.

Definition: a discharge logger stores event data required for audits and PSC queries. Example: logs show exact time and coordinates of each allowed discharge, aiding compliance and ESG reporting.

Georim oily water separators — models and capacities

Summary: Georim offers OWS units in several sizes to suit machinery space output and vessel type.

Definition: OWS models differ by flow rate, footprint and power needs. Example: select a model that matches bilge flow and ease of retrofit to avoid major piping changes. Tip: request a mini-datasheet from your agent before purchase.

Compliance, Calibration & Regulations

Summary: Georim equipment must meet IMO and MEPC rules and carry timely calibration certificates to satisfy PSC and class.

Definition: MARPOL Annex I restricts oil discharge to 15 ppm and requires approved monitoring systems. For official guidance see the IMO MARPOL page: IMO MARPOL and MEPC references: IMO MEPC.

How often must a 15 ppm bilge alarm be calibrated?

Summary: Annual calibration is the common industry schedule, with additional checks at intermediate or special surveys.

Definition: calibration confirms the sensor reads accurately across the measurement range. Example: operators often schedule calibration before high-risk port calls to avoid PSC findings. Tip: keep dated certificates and photos in the ship file.

Relevant IMO/MEPC rules and documentation

Summary: MEPC documents set performance standards and testing procedures for bilge alarms and discharge monitoring devices.

Definition: MEPC guidance covers alarm thresholds, testing, and record keeping. Example: bring the device manual and calibration certificate on inspections to demonstrate conformity.

Service, Ports & Turnaround

Summary: Local agents and authorized service providers attend Dubai, Jebel Ali, Fujairah and nearby anchorages for fast calibration and repairs.

Definition: port coverage lists where engineers will attend for onboard work. Example: Al Ghwasa and regional partners serve Fujairah, Khorfakkan, Jebel Ali, Abu Dhabi and Sohar with typical lead times quoted per request.

Ports covered and typical response times

Summary: Response time depends on anchorage, berth and spare availability; typical onsite windows range from same-day for urgent calls to 48 hours for planned jobs.

Definition: lead time is influenced by clearance and access. Example: pre-book calibration to secure a slot during tight port calls.

Onboard calibration, repair and emergency attendance

Summary: Authorized engineers perform onboard calibration, repairs and retrofits with class-acceptable documentation.

Definition: engineers use manufacturer test kits and issue calibration certificates. Example: combine OWS service with bilge alarm checks to save port time and cost.

Comparisons & Buying Decisions

Summary: Georim competes on proven products and regional support; buying decisions weigh service coverage, parts availability and TCO.

Definition: total cost of ownership includes purchase, installation, calibration and spare parts. Example: choose Georim if you value local authorized support and a clear audit trail.

Why choose Georim GBA-155 over other bilge alarms?

Summary: Georim offers certified 15 ppm performance with an associated Green Box logger and authorized regional support.

Definition: combined product and service reduces downtime and audit risk. Example: many regional operators prefer a single-source solution for equipment and on-site service.

Retrofits, spare parts, and total cost of ownership

Summary: Retrofits are usually feasible; genuine spare kits from authorized agents reduce long-term costs and delays.

Definition: spare availability shortens repair windows. Example: order critical spares to be held in Dubai if you operate frequently in the Gulf.

Summary: 

Georim systems meet the technical needs for MARPOL Annex I if installed and maintained by an authorized agent in the UAE. Use local representation for genuine parts, timely calibration and class-accepted certificates; pre-book service slots in busy ports to avoid last-minute issues.

FAQ

Is Al Ghwasa an authorized Georim agent in the Middle East?

Yes. Al Ghwasa lists Georim representation and handles sales, service and spares for the UAE region (agent page).

Can Georim systems be calibrated during a bunkering call?

Often yes. Engineers can attend during bunkering or anchorage, but you should pre-book to meet clearance and timing constraints.

Will calibration certificates be accepted by PSC and class?

Yes, when issued by an authorized agent using manufacturer procedures; keep originals and supporting test records onboard for inspections.

Related Posts

Leave a Reply

Your email address will not be published. Required fields are marked *